  "visual_id": "C01-calibrated-nuclear",
  "title": "Ordinary calibration and unidentified field response",
  "classification": "conditional_numerical_experiment",
  "run_ids": [
    "20260929T024206209567Z-P1-renormalized"
  ],
  "claim_ids": [
    "C02"
  ],
  "input_files": [
    {
      "path": "runs/20260929T024206209567Z-P1-renormalized/capture-reserved-predictions.csv",
      "sha256": "c6bf87d207c71ac9cd4377082b1631b5cff1b7e664c999dde1c8692876d6508e"
    },
    {
      "path": "runs/20260929T024206209567Z-P1-renormalized/unidentified-field-response.csv",
      "sha256": "2a51d34e8b47c0fab290a0e8466a36defb16bb66408103dd6052f9b6edb423ba"
    }
  ],
  "configurations": {
    "P1-renormalized": {
      "regulator_range_factors": [
        0.8,
        1.0,
        1.2
      ],
      "theta": [
        0.0,
        0.2,
        0.5,
        1.0
      ],
      "unmeasured_contact_response_scenarios": [
        -1.0,
        0.0,
        1.0
      ],
      "capture_training_energies_MeV": [
        0.3,
        1.0,
        2.3
      ],
      "capture_reserved_energies_MeV": [
        0.45,
        0.65,
        0.85,
        1.25,
        1.6,
        1.9,
        2.15
      ]
    }
  },
  "assumptions": {
    "P1-renormalized": [
      "New ordinary-baseline calibrations are explicit alternatives, not a correction attributed to either publication.",
      "The journal version was checked: its regulator equation retains the same dimensional ambiguity as arXiv.",
      "Two-nucleon scans isolate pion/kinetic changes with fixed heavy exchanges; short-distance response is unmeasured. Scenarios are not a probability distribution.",
      "The deuteron energy and three capture-curve values are calibration data. Reserved capture energies test interpolation of a published curve, not independent experiments.",
      "Neither calibrated ordinary counterterms nor numerical accuracy identifies their field derivatives or a many-body Hamiltonian."
    ]
  },
  "plotted_values": {
    "path": "C01-calibrated-nuclear-data.json",
    "sha256": "62c10a97c6085ad2a39ae3614328d282c9692f4b56889030518d9a5816445da7"
  },
  "caption": "Three capture energies calibrate one E1 counterterm; seven other source-curve energies are reserved. The shaded drawing-width scale is not measured experimental covariance. Explicit OBE fits agree on ordinary deuteron binding but diverge under independent contact-response scenarios and predict an unwanted bound singlet. These fits do not resolve the printed source convention.",
  "alt_text": "Reserved capture discrepancies are below one percent. Two-nucleon energy curves agree at the ordinary calibration point and spread as the assumed field response increases.",
  "generator": "src/metastable/experiment_report.py",
  "generator_sha256": "00ba19fa7e51a7b74e16e13e473754e9c41eedcadda657586c8f5ceb1b90100f",
  "command": "python run.py full experiment-report",
  "output_sha256": {
    "svg": "defad7060ca440b4a63ad542961ef9ef383d2dc7dd0a3d3e2ed6082ee04b1af8",
    "png": "01a7ca0bd85bb0d6b44befd5c92db78598668f5473c93f6115195043dfe51247"
  }
}