{
  "visual_id": "V26",
  "title": "A gravitational test needs a specified source",
  "classification": "new_simulation",
  "status": "validated_within_scope",
  "experiment_ids": [
    "E22-gravity",
    "E17-pockets"
  ],
  "run_ids": [
    "20260927T160536990169Z-E22-gravity",
    "20260927T155224454500Z-E17-pockets"
  ],
  "model_ids": [
    "M7-same-pocket-lensing-and-spherical-source-null",
    "M7-conserved-dark-Dirac-thin-wall-pocket"
  ],
  "claim_ids": [
    "C07"
  ],
  "input_files": [
    {
      "path": "runs/20260927T160536990169Z-E22-gravity/same-model-lensing.csv",
      "sha256": "820fad2934943474a2cd60321616f81ebb25682ef4f25032a208dfab21e8cf71"
    },
    {
      "path": "runs/20260927T160536990169Z-E22-gravity/TT-source-control.csv",
      "sha256": "f2b74cd1289e220fc8e3e0b3d7028ef416c4de774c1f2f88334f96400bc41fc9"
    }
  ],
  "plotted_values": {
    "path": "V26-data.json",
    "sha256": "f6b1096d02de88db808b024c60755321552a894794e4a6fa1a9324a20a7ad8a2"
  },
  "source_ids": [
    "E17-Fermi-ball",
    "E22-acoustic"
  ],
  "units": "Explicit axis labels and unit-bearing source columns; normalized quantities are defined in the caption.",
  "transformations": [
    "Saved numerical outputs only; physical interpolation, selection and normalization are described by the generator and caption."
  ],
  "uncertainty_type": "Numerical controls, published errors, and declared model/nuisance scenarios remain distinct; no biological threshold.",
  "validity_limits": [
    "A component calculation does not establish an observationally allowed complete history."
  ],
  "caption": "The same E17 pocket masses/radii give lens geometry for a declared 10-kpc lens and 50-kpc source. There is no abundance or survey-based detection forecast. Right: an exactly spherical stress source has zero tensor radiation up to numerical roundoff; imposed quadrupoles are method controls, not predicted transitions. A thermal sound-wave formula is not applied to these spherical events. Ordinary-matter coupling remains zero.",
  "alt_text": "Lens compactness varies with pocket mass. Spherical tensor amplitude sits at roundoff while artificial nonspherical controls give a finite projection.",
  "render_command": "uv run --offline --frozen python run.py full render",
  "generator_sha256": "fa75ece843491c857348bd38d22cfeeae732a8bb9caa8c1921182f783c2cc6a4",
  "extension_generator_sha256": "4cef7f7e2f45594db1c8eb981fb50ae736aad43e6708d1f12826d99b57a40cce",
  "output_sha256": {
    "svg": "d98e2cfe698c6cf428874db2ddb1fdc2c5c3744c68f4410d44907824f0cfb4f0",
    "png": "f12e2f0cfdc363391d9dd495e45e0e81c8f8d3264eacd94edcaf6ed3df1881bd"
  }
}
